OVERVIEW
    AT811 with 100Hz, 120Hz, 1kHz and 10kHz test frequencies, and provide 0.3V, 1V test levels, so that it can fully meet the use of general production sites.
FEATURES
  • LCD Display
  • Correction: OPEN and SHORT
  • Comparator Function: P1,P2,P3,NG,AUX
  • Beep Alarm
SPECIFICATIONS
Test FunctionsL,C,R,Z,D,Q
Accuracy0.25%
Measurement Frequency100Hz,120Hz,1kHz,10kHz
Measurement RangeAuto/Hold, 6 ranges
Measurement Speed5 次 / 秒,11 次 / 秒
Display RangeL: 0.01μH-9999H
C: 0.01pF-9999μF
R,Z: 0.0001Ω - 99.99MΩ
D, 0.0001–9.999
Q: 0.0001–999.9
Source Resistance30Ω,100Ω
Display Reader29999
Equivalent CircuitSerial and Parallel
Signal Level0.3Vrms 和 1Vrms
Comparator5 Bins: P1/P2/P3/AUX/NG
Comparator ModeSEQ/ABS/PER
AdjustmentOPEN/SHORT Zeroing
Beep FeatureP1, P2, P3, AUX, NG, OFF
Power SupplyAC 198V-240V, 50Hz-60Hz
10W MAX
Dimension & Weight220mm(W) x 85mm(H) x 259mm(L)
2kg
APPLICATIONS
    Componets and materials measurement such as Inductor, Magnetic core, Ferrite core, Capacitor, Transformer and etc.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL501

ATL501

Kevin clib

OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT2811

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.25%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: Auto/Hold, 6 ranges
  • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

Compare

AT2816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2816B

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2817

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (16 Points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

Compare

AT3810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~200kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT610D

  • Test Functions: C,D
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: AUTO/HOLD 6 Ranges
  • Measurement Speed: 3times/s, 8 times/s, 20 times/s

Compare

AT810

  • Test Functions: L,C.R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD, 6 Ranges
  • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

Compare

AT810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

Compare

AT810D

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
  • Measurement Speed: 2 times/s, 5 times/s

Compare

AT817D

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
  • 20kHz,40kHz,50kHz, 100kHz
  • Measurement Range: AUTO/HOLD 6 Ranges

Compare

AT825

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT826

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s