AT3816A Precision LCR Meter
ACTIVE
10Hz~200kHz
DCR
Send Email to us
RS232USB-232HANDLER
SCPIMODBUS
DATA LOGGERUSB-DISK
OVERVIEW
    The newly upgraded AT3816A adopt true color TFT-LCD display. Displayed in large fonts, readings are more intuitive.

    AT3816A with continuous frequency point of 10Hz~200kHz with a resolution of 0.001Hz. Test signal level 0.01Vrms ~ 2.00Vrms (10mV step), add DCR measurement and internal DC bias (DC BIAS, ±2.5V) .

    AT3816A can test the 4 parameters of the component at the same time. Each parameter can be arbitrarily configured. The newly improved instrument realizes full 6-bit display of the main and auxiliary four parameters.

    Can scan 10 kinds of frequencies or level lists, and can also be used for 3 groups.

    User frequency is corrected to improve accuracy.

    Built-in comparator, through the HANDLER interface combined with PLC to complete the automatic sorting of components.

    Built-in RS232/RS485/USB interfaces and GPIB inteface optional, SCPI and Modbus support.
FEATURES
  • True color TFT-LCD display.
  • Store 999 LCD screen files, trigger delay, automatic level control (ALC)
  • Correction function: full-scale open circuit and short-circuit sweep frequency clear, three groups of users point frequency calibration.
  • Multi-frequency test: support 10 frequency scan tests
  • Multi-level test: support 10 level scan tests
  • 10 sets of file management for full storage of instrument status, list scan settings and comparator settings.
  • Enhanced comparator (sorting) function: Programmable P1~P9 Nine-segment sorting, main parameters HI, IN, LO display and output, NG, AUX, SREJ, IDX, EOM, etc. Output.
  • Absolute deviation (ABS) comparison mode, relative deviation (PER) and order (SEQ) comparison.
  • Switchable accessory file (AUX) sorting.
  • Programmable from 1 to 200 times to provide stability.
  • Custom sorting results are heard.
  • Built-in RS232/RS485/USB interfaces and Handler interface, GPIB interface optional.
  • Protocol: SCPI and Modbus.
  • 1000V super shock protection
SPECIFICATIONS
APPLICATIONS
    Componets and materials measurement such as Inductor, Magnetic core, Ferrite core, Capacitor, Transformer and etc.
    Laboratory quality control
    Feed inspection
    Component sorting
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL103

ATL103

USB通讯线

ATL108A

ATL108A

ATL108A

ATL501E

ATL501E

ATL501E

ATL508A

ATL508A

ATL600

ATL600

ATL601

ATL601

OPTIONS
NONE
SOFTWARE
Applent Communication Assist
Rev.4.23

CHINESE

Application

FREEWARE

2.4MB

RAR

CH340 USB Driver
Rev.A1.0

Driver

SYSTEM

0.2MB

RAR

AT3818 Datalogger (External Trigger)
Rev.A1.0

CHINESE

Application

FREEWARE

3.2MB

RAR

Contact Anbai
Your name*
Your company*
Your phone number (+Country Code)
Your email*
Content*
RELATED PRODUCTS

Compare

AT3818

  • Sensor:
  • Accuracy:
  • Range:
  • Resolution:
  • Channels:

Compare

AT4108

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4508

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4516

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4724

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4724V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4732V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4740V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4748V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4756V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4764V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 16 channels;

Compare

AT4816

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channels;

Compare

AT4824

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels;

Compare

AT4832

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels;

Compare

AT4540

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 40 channels; 128 channels are available

Compare

AT4548

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 48 channels; 128 channels are available

Compare

AT4556

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 56 channels; 128 channels are available

Compare

AT4564

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 64 channels; 128 channels are available

Compare

AT4572

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 72 channels; 128 channels are available

Compare

AT4580

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 80 channels; 128 channels are available

Compare

AT4588

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 88 channels; 128 channels are available

Compare

AT4596

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 96 channels; 128 channels are available

Compare

AT45104

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 104 channels;

Compare

AT45112

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 112 channels; 128 channels are available

Compare

AT45120

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 120 channels; 128 channels are available

Compare

AT45128

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 128 channels; 128 channels are available

Compare

AT4900

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 200 channels;‌(Customizable number of channels, incremented/decremented by 10 channels each time)

Compare

AT4708A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708AH

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

微信客服


👩‍🦰Lucy@applent.com
Wechat&Whatsapp+86 18625285980 whatsapp 👩🏻queena@applent.com
Wechat&Whatsapp+86 13775247528 whatsapp

Email

Email
lucy@applent.com
queena@applent.com

Send Message

Privacy | Term of Use | Help
©2005-2026 Changzhou Applent Instruments Ltd. 苏ICP备13026254号