AT58612 Film capacitor charge and discharge tester
ACTIVE
Send Email to us
OVERVIEW
    The AT58612 capacitor testing system is applied to capacitor manufacturers, capacitor users, and capacitor detection measurement units, and can perform DV/DT testing. The method is to first charge the tested capacitor and measure the DV/DT value during the rapid discharge process of the capacitor. The signal voltage, frequency, and discharge resistance can be set as needed. The signal is applied to both ends of the tested capacitor, and the test cycle is set. The capacitor is continuously tested, and the temperature rise, capacity, and loss of the capacitor are continuously monitored and recorded during the test process. Finally, evaluate whether the capacitor meets the requirements based on the temperature rise, capacity, and loss changes of the capacitor. By using this method for detection, whether it is the characteristics of the material (polarization characteristics), or the differences in structural design (plate resistance) and losses, they can be intuitively reflected through the changes in temperature rise and capacity loss of the capacitor.
FEATURES
  • Measure DV/DT values during the rapid discharge process of capacitors.
  • The signal voltage, frequency, and discharge resistance can be set as needed
  • Continuously monitor and record the temperature rise, capacity, and loss of capacitors, and evaluate whether the capacitors meet the requirements based on their temperature rise, capacity, and loss changes.
SPECIFICATIONS
● Power module※ Programmable constant voltage and constant current source ※
        Input voltage380V AC 50Hz
        Output voltage range100~1200V(This parameter is for reference only and can be customized according to requirements)
        Output current range10A
        Maximum output power12000W
        Power module voltage setting/readback accuracy± 2%, ± 5dgt (set value=charging and discharging set voltage, the readback value can be viewed when the internal parameters are turned on)
● Charging module※ Constant current charging module ※
        Constant current charging rangeAbout 9A
●Discharge moduleElectronic load
        Pulse carrying current rangeMAX 3200A (theoretical value, actual value depends on external inductance and measured capacitance, internal 3200A current limitation of the instrument can reduce the damage rate of misoperation)
        Charge and discharge parameters (user specific parameters)
        Discharge modeExternal inductor discharge
        TriggerInternal/PLC/232/485
        Voltage100~1200V
        Measurement timing (single product measurement time)1~1200
        Test frequency (charge discharge frequency)1Hz ~200Hz
        Discharge current settingInternal fixed limit MAX 3200A (theoretical value, actual value depends on external inductance and measured capacitance, internal 3200A current limit of the instrument can reduce the damage rate of misoperation)
        Capacitance capacity20μF~300μF, this parameter needs to be set by the user according to the actual situation
        External inductance12μH~100μH, this parameter needs to be set by the user according to the actual situation
        Open circuit detectionSample the discharge current, and if the sampled value is particularly small, determine an open circuit
        Charging undervoltage detectionYes, it can detect incorrect products and avoid damaging the instrument in case of timing errors on the machine
        Over temperature detectionYes
InterfaceRS232/RS485/handler interface (for connecting to PLC)
Programming languageSCPI and Modbus(RTU)
Power SupplyThree phase five wire
PowerMaximum 12000W
Weight100kg
DOCUMENTATION
NONE
ACCESSORIES
STANDARDS
NONE
OPTIONS
NONE
SOFTWARE