AT526C AC Low ohm Meter (Battery Internal Resistance Meter)
ACTIVE
OV & CV Mode
RS232HANDLER
RS485OPTIONS
SCPI
USB-DISK
OVERVIEW
    AT526C is a newly designed multi-function battery tester with high precision and high stability. The battery can be tested with load and no-load, (the loading time can be set arbitrarily from 0.1S-9999.9S); controlled by high-performance ARM microprocessor. True color 3.5 inchLCD display in Chinese and English, more convenient to operate. Applied to the voltage and internal resistance measurement of battery loaded and unloaded, the new and improved sampling circuit can measure any kind of battery. In addition, the instrument has a professional sorting function, and the sorting sound setting is applied to the automatic sorting system to complete the automatic assembly line test. It can also be equipped with a USB interface for remote control and data acquisition and analysis, which is very suitable for mass production of batteries.
FEATURES
  • Adopt vector method and measure multi parameter silmutaneously
  • Comparator(sorting) function
  • Detection of damage test wire
  • Compatible with SCPI
  • Brand-new improved sampling circuit
SPECIFICATIONS
ParametersAC Resistance, DC voltage
AccuracyResistance:0.5% ; Voltage:0.01%
RangeResistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
Signal SourceAC 1kHz,Test current:<150mA
Range7 ranges, auto & manual
Speed145 times/second、30 times/second、10 times/second、1times/second
Result DisplayShow,ΔABS,Δ%,θ, sorting results
Display MaxResistance:33,000 Voltage:1,200,000
Adjustmentfull range short - circuit correction
Comparator16-bin sorting RHI/RNG/RLO output VHI/VNG/VLOOutput absolute value tolerance±TOL sorting percentage tolerance TOL sorting Order comparison sorting
TriggerInternal trigger, manual trigger, external trigger and remote trigger
InterfaceRS-232C , Handler(PLC Interface)
OptionsATL506A Test probe, ATL506 Test meter stick
PowerVoltage:195VAC~245VAC Frequency:50Hz Power:15VA
Dimensions264 x107x350 mm
Mass4kg
AccessoriesATL505 Kelvin test leads、 ATL108 RS232 communication cable
Other functionsDetection of damage test wire,TFT -LCD display, keypad lock and data hold function, internal memory and U-disk record
APPLICATIONS
    All kinds of contact resistance measurement
    Li-battery, alkaline cell and lead accumulator determination of degradation and evaluation of lifetime
    UPS test online and lead accumulator factory inspection
    ESR test of super capacitor
DOCUMENTATION
DOCUMENTS
DATASHEET CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS
NONE
OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT520L

  • Parameters: AC Resistance , DC voltage
  • Accuracy: R: 0.3%, V: 0.05%
  • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
  • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
  • Range: Automatic and manual with 6 ranges

Compare

AT525

  • Parameters: ACR DCV
  • Accuracy: R:0.5%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
  • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
  • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
  • Range: Automatic, Manual, Norminal, 4 ranges

Compare

AT526

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT526B

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
  • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
  • Range: Automatic & Manual , 5 ranges

Compare

AT527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT527A

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT527B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

Compare

AT528

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 6 ranges, automatic, manual, nominal

Compare

AT528L

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 4 ranges, automatic, manual, nominal

Compare

AT526G

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT527F

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT572B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527K

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1500.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT529

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529A

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~200.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~800.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~1000.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT527S

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~2000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT2527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT2527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~60.0000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.
Privacy | Term of Use | Help
©2005-2024 Changzhou Applent Instruments Ltd. 苏ICP备13026254号