OVERVIEW
    AT527K adopts high-performance 32-bit ARM microprocessor-controlled miniature benchtop instrument for automatic real-time detection. The instrument adopts 4.3

    Inch true color LCD display, using full touch operation, a brand-new instrument interaction experience.

    The instrument can test the resistance of 0.0001mΩ~3.3kΩ, the DC voltage of 0.00001~1500.00V, the resistance is 33000 digits, and the voltage is 100000 digits. AT527K has the characteristics of high precision, high resolution and ultra-high-speed measurement at the same time, providing 0.5% resistance accuracy and 0.01% voltage accuracy, and the measurement speed can reach 55 times/second.

    The instrument is used for professional sorting function. It is equipped with a Handler (PLC) interface as standard, and independently outputs resistance HIGH/IN/LOW signal and voltage HIGH/IN/LOW signal, which can fully cope with high-speed automatic sorting system to complete automatic assembly line test. At the same time, the enhanced IO signal can directly drive the power relay and signal relay.

    The instrument has built-in RS-232C interface and USB-232 interface. The instrument comes standard with general data acquisition software, with its own database function and Excel.

    The export function can be effectively used for remote control and data acquisition and analysis.

    The instrument uses enhanced computer remote control command set of Anbai Instrument, compatible with SCPI(Standard Command for Programmable Instrument) and Modbus Protocol(Modbus has become National standard GB/T19582-2008). It is used for automatic sorting system to fullfill full automatic assembly line inspection, capable of completing remote control and data collection function with high efficiency.

    Adopting new and improved designed AC resistance test principle, it can be used for almost all battery internal resistance test, including the assembly line inspection of Lithium battery, Lead acid battery, button battery ,etc.
FEATURES
  • 33000 AC resistance readings, 1000,00DC voltage reading
  • Resistance test range: 0.0001mΩ~3.3000kΩ
  • Voltage test range: 0.00001V~1500.000VDC
  • 0.5% resistance accuracy
  • 0.01% voltage accuracy
  • HANDLER interface
  • RS-232C and USB communication interface
  • U disk real-time storage full touch operation
SPECIFICATIONS
ParametersACR, DCV
AccuracyAccuracy of resistance: 0.5%,voltage: 0.01%
RangeTest range: 0.0001mΩ~3kΩ & 0.00001~1500.00V
Signal Source1kHz, frequency stability: 20ppm
Range3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.
SpeedAll channels open and manual operation: slow 3 times/s, medium 20 times/s, fast 40 times/s , high-speed 70 times/s.
Result Displayshow, ΔABS,Δ%,θ, sorting result
Display MaxR:33,000 V:800,000
Adjustmentshort-circuit reset full range
Comparatorsorting function: RHI/RNG/RLO output, VHI/VNG/VLO output, NG/OK output. compare way:Absolute value tolerance ±TOL sorting: the absolute deviation between the measured value and the nominal value is compared with the limits of each file. Percent tolerance %TOL sorting: the percentage deviation between the measured value and the nominal value is compared with the limits of each file. Sequential comparison sorting: the measured value is directly compared with the upper and lower limits
TriggerInternal, Manual, External and remote
Cantact CheckingBroken Wire and Open Circuit Detection
InterfaceHANDLER, RS-232C, USB
OptionsATL527A
PowerV:195VAC~245VAC Fre:50Hz Power:15VA
Dimensions264 x107x350mm
Mass4KG
AccessoriesATL527 kelvin test cable, ATL108 RS232 cable
Other functions4.3 inch TFT-LCD color display, full touch operation
APPLICATIONS
    Energy storage solutions
    Various contact resistance tests
    Determination of deterioration and life evaluation of alkaline batteries, lead storage batteries, and lithium batteries
    Battery factory inspection
    Super Capacitor Equivalent Resistance (ESR) Measurement
DOCUMENTATION
DOCUMENTS
DATASHEET CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATL527

ATL527

AT527 kelvin test clip

ATL527A

ATL527A

AT527 Probe test pen

OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT520L

  • Parameters: AC Resistance , DC voltage
  • Accuracy: R: 0.3%, V: 0.05%
  • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
  • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
  • Range: Automatic and manual with 6 ranges

Compare

AT525

  • Parameters: ACR DCV
  • Accuracy: R:0.5%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
  • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
  • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
  • Range: Automatic, Manual, Norminal, 4 ranges

Compare

AT526

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT526B

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
  • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
  • Range: Automatic & Manual , 5 ranges

Compare

AT526C

  • Parameters: AC Resistance, DC voltage
  • Accuracy: Resistance:0.5% ; Voltage:0.01%
  • Range: Resistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: 7 ranges, auto & manual

Compare

AT527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT527A

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT527B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

Compare

AT528

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 6 ranges, automatic, manual, nominal

Compare

AT528L

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 4 ranges, automatic, manual, nominal

Compare

AT526G

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT527F

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT572B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT529

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529A

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~200.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~800.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~1000.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT527S

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~2000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.