AT4808 Handheld Multi-channel Temperature Meter
ACTIVE
USB-HIDUSB-232
SCPI
DATA LOGGERUSB-DISK
OVERVIEW
    AT4808 handheld multi-channel temperature meter is a new upgraded with ARM micro processor. multi-channel sampling and parallel test, can sampling, alarm and communication transmission to 8 channels simultaneously. compatibility various kinds of temperature sensors, fast response, data stable and with Break even detection function.

    The temperature test resolution 0.1 ℃.

    AT4808 support K/N/E/J/T/R//S/B thermocouples. test temperature -1200℃ to 1300℃.

    AT4808 with RS-232 & USB interface, data collection,alalysis and printing by connection PLC.

    The instrument is equipped with RS-232 interface and USB interface as standard, and provides free communication. Data collection, analysis and printing can be easily realized through PC software.

    AT4808 uses a sturdy and anti-vibration shell, which can work in harsh environments. Fully isolated digital and analog signals, ## (can be live test (isolation voltage 230Vrms, 330VDC)) ##, safe and reliable. AT4808 comes standard with U disk interface and supports real-time data storage.
FEATURES
  • TFT-LCD True-color LCD display,three kinds of character font.
  • Fast,medium and low scanning speed.
  • Cold Junction Compensation
  • Standard configuration U-disk and Mini-USB interface,support mass storage device.
  • Broken thermocouple checking function
  • Allocated channel scanning
  • Standard configuration ATS48 data acquistion software
  • 8.4V, Li, 2200mA rechargeable battery
SPECIFICATIONS
GraduationThermocouple:J/K/T/E/S/N/B/R
Accuracy0.2%+1℃
Range-200℃~1800℃ (variation depend on graduation)
Resolution0.1℃
Channels8 channels; 128 channels are available
Speedfast: 100ms/channel, medium:500ms/channel, slow: 1s/channel
CorrectionError correction for each channel
Comparatorhigh & low beep function for each channel
InterfaceRS232C, U-disc, USB
SoftwareATS45 data acquisition software
Cold JunctionAccuracy: 0.5℃
Other FunctionsTFT-LCD True color display, broken thermocouple check function
Power SupplyV: 85VAC~260VAC Fre:50Hz/60Hz Power:10VA
Dimension & Weight216x88x300mm weight:3kg
AccessoriesK thermocouple 8 channels (2 meters/ channel)
APPLICATIONS
    Apply to home appliance,motors,heating appliance,temperature controller,transformer,oven,thermal protector,power supply,lighting,electric power,LED and so on.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL105

ATL105

MiniUSB通讯电缆

ATL804

ATL804

锂电池

ATL909

ATL909

直流电源适配器

ATL909

ATL909

直流电源适配器

K

K

K型热电偶

OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT4108

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4310

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 5 channels; thermocouple 10 channels; scan channel can off arbitrarily

Compare

AT4320

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 10 channels; thermocouple 20 channels; scan channel can off arbitrarily

Compare

AT4340

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD20 channels; thermocouple 40 channels; scan channel can off arbitrarily

Compare

AT4508

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4516

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃(
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4724

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4724V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4732V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4740V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4748V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4756V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4764V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;
Privacy | Term of Use | Help
©2005-2024 Changzhou Applent Instruments Ltd. 苏ICP备13026254号