AT4756V Datalogger
ACTIVE
USB-232
RS232LANOPTIONS
SCPI
DATA LOGGERUSB-DISKSD CARD
OVERVIEW
    AT47V series multi-channel temperature tester adopts high-performance ARM microprocessor control, 7-inch color LCD screen display, touch screen operation, convenient to view temperature value, temperature change curve, histogram, etc., can simultaneously collect multi-channel temperature data. Ultra-low alarm and communication transmission, AT47V series can collect 64 channels of temperature data, compatible with K/N/E/J/T/R/S/B thermocouples, fast response speed, stable data, and has a broken couple detection function . Each channel can be set individually and calibrated independently.

    The instrument supports USB communication, and data collection, analysis and printing can be realized through standard computer software. Support USB disk storage, real-time storage of sampling data. The user can independently correct each channel of data.

    The AT47 series adopts fully isolated digital and analog signals, ## (can be tested on-line (isolation voltage 230V rms, 330VDC), support PT100, CU50, safe and reliable.
FEATURES
  • 7 inches TFT true color LCD display
  • Histogram display, graph
  • Highest value, lowest value, average value display
  • Cold junction compensation
  • Standard USB disk interface, support for large-capacity storage devices.
  • Standard RS232C interface and USB interface
  • Automatic detection of broken couple
  • Specified channel scan
  • Standard data acquisition software
SPECIFICATIONS
GraduationThermocouple:J/K/T/E/S/N/B/R,PT100,CU50
Accuracy0.2%+1℃
Range-200℃~1800℃ (variation depend on graduation)
Resolution0.01℃
Channels8 channels;
Speedfast: 500ms/channel, slow: 1s/channel
CorrectionError correction for each channel
Comparatorhigh & low beep function for each channel
InterfaceRS232C, U-disc, USB
SoftwareATS45 data acquisition software
Cold JunctionAccuracy: 0.5℃
Other FunctionsTFT-LCD True color display, broken thermocouple check function
Power SupplyV: 85VAC~260VAC Fre:50Hz/60Hz Power:10VA
Dimension & Weight216x88x300mm weight:3kg
AccessoriesK thermocouple 8 channels (2 meters/ channel)
APPLICATIONS
    Suitable for multi-point temperature testing of manufacturers and quality inspection departments in home appliances, motors, electric appliances, thermostats, transformers, ovens, thermal protectors, power supplies, lighting, electric power, LED, etc.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATUSB

ATUSB

K

K

K型热电偶

OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT4108

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4310

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 5 channels; thermocouple 10 channels; scan channel can off arbitrarily

Compare

AT4320

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 10 channels; thermocouple 20 channels; scan channel can off arbitrarily

Compare

AT4340

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD20 channels; thermocouple 40 channels; scan channel can off arbitrarily

Compare

AT4508

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4516

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃(
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4724

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4724V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4732V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4740V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4748V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4764V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 16 channels;
Privacy | Term of Use | Help