AT4516 Multi-Channel Temperature Meter
ACTIVE
RS232USB-232
SCPI
DATA LOGGERUSB-DISK
OVERVIEW
    AT4516 multi-channel temperature meter is a new upgraded with ARM micro processor. multi-channel sampling and parallel test, can sampling, alarm and communication transmission to 8 channels simultaneously. compatibility various kinds of temperature sensors, fast response, data stable and with Break even detection function.

    The temperature test resolution 0.1 ℃.

    AT4516 support K/N/E/J/T/R//S/B thermocouples. test temperature -1200℃ to 1300℃.

    AT4516 with RS-232 & USB interface, data collection,alalysis and printing by connection PLC.

    The instrument is equipped with RS-232 interface and USB interface as standard, and provides free communication. Data collection, analysis and printing can be easily realized through PC software.

    AT4508 uses a sturdy and anti-vibration shell, which can work in harsh environments. Fully isolated digital and analog signals, ## (can be live test (isolation voltage 230Vrms, 330VDC)) ##, safe and reliable. AT4508 comes standard with U disk interface and supports real-time data storage.
FEATURES
  • Scan speed: Fast/Med/Slow
  • Cold Junction Compensation
  • TFT True Color LCD Display.
  • Interface: RS232C and USB Slaver Interface
  • USB-Disk Interface
  • Automatic detection of burnout
  • Specified channel scan
  • AT45 data acquisition software
SPECIFICATIONS
GraduationThermocouple:J/K/T/E/S/N/B/R
Accuracy0.2%+1℃
Range-200℃~1800℃ (variation depend on graduation)
Resolution0.1℃
Channels16 channel; 128 channels are available
Speedfast:500ms/channel, slow: 1s/channel
CorrectionError correction for each channel
Comparatorhigh & low beep function for each channel
InterfaceRS232C, U-disc, USB
SoftwareATS45 data acquisition software
Cold JunctionAccuracy: 0.5℃
Other FunctionsTFT-LCD True color display, broken thermocouple check function
Power SupplyV: 85VAC~260VAC Fre:50Hz/60Hz Power:10VA
Dimension & Weight216x88x300mm weight:3kg
AccessoriesK thermocouple 16 channels (2 meters/ channel)
APPLICATIONS
    Suitable for multi-point temperature testing by manufacturers and quality inspection departments in home appliances, motors, electric heating appliances, thermostats, transformers, ovens, thermal protectors, power supplies, lighting, electricity, LEDs and other industries
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL103

ATL103

USB通讯线

ATL108

ATL108

RS232通讯电缆

ATN2

ATN2

K

K

K型热电偶

OPTIONS

ATN4508

ATN4508

8路外接模块

SOFTWARE
AT45/47 Datalogger Software
Rev.6.31

Application

FREEWARE

5.3MB

RAR

AT42/45/47 Datalogger Software
Rev.6.96

Application

FREEWARE

5.6MB

RAR

RELATED PRODUCTS

Compare

AT4108

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4310

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 5 channels; thermocouple 10 channels; scan channel can off arbitrarily

Compare

AT4320

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 10 channels; thermocouple 20 channels; scan channel can off arbitrarily

Compare

AT4340

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD20 channels; thermocouple 40 channels; scan channel can off arbitrarily

Compare

AT4508

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4524

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃(
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4724

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4724V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4732V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4740V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4748V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4756V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4764V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 16 channels;
Privacy | Term of Use | Help