AT4202 Handheld Multi-channel Temperature Meter
ACTIVE
USB-232
SCPI
DATA LOGGERUSB-DISK
OVERVIEW
    AT4202 handheld multi-channel temperature meter adopts high-performance ARM micro processor, can collect multi-channel temperature data simultaneously and response quickly. AT4208 has the function of checking broken thermocouple, high/low beep function and communication transmission. Ultra-low power consumption and high density SMD assembly technology. True-color TFT liquid crystal display, keypad and touch screen double control. It is Li- battery powered. USB communication. Switch in both English and Chinese.

    The standard computer software can realize the data analysis.
FEATURES
  • TFT-LCD True-color LCD display
  • touch screen
  • Fast,Medium,Low scanning speed
  • Cold Junction Compensation
  • Mini-USB interface
  • The function of broken thermocouple checking
  • ATS42 data acquisition software
  • 8.4V, Li battery powered
SPECIFICATIONS
GraduationThermocouple:J/K/T/E/S/N/B/R
Accuracy0.2%+1℃
Range-200℃~1800℃ (variation depend on graduation)
Resolution0.1℃
Channels2 channels
Speed1s/ channel
CorrectionError correction for each channel
Comparatorhigh & low beep function
InterfaceMini-USB
SoftwareATS42 data acquisition software
Cold JunctionAccuracy: 0.5℃
Other Functions2.8 inch color 16M TFT-LCD display, touch screen, USB communication, compatible SCPI order set, Chinese/Englsih Language, adjustable back light, auto power off
Power SupplyInput:100-240V~50/60Hz 0.35A output:9V 1A DC
Dimension & Weight90x190x31mm weight:400g
AccessoriesK thermocouple 2 channels (2 meters/ channel) ATL909 DC adaptor, ATL805 Li battery, USB communication cable, ATS42 data acquisition software
APPLICATIONS
    Apply to home appliance,motors,heating appliance,temperature controller,transformer,oven,thermal protector,power supply,lighting,electric power,LED manufacturers,quality supervision department's requirements for multiple points measurement.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL105

ATL105

MiniUSB通讯电缆

ATL805

ATL805

锂电池

ATL909

ATL909

直流电源适配器

ATL909

ATL909

直流电源适配器

OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT4108

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Graduation: Thermocouple:J/K/T
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4204

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4310

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 5 channels; thermocouple 10 channels; scan channel can off arbitrarily

Compare

AT4320

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD 10 channels; thermocouple 20 channels; scan channel can off arbitrarily

Compare

AT4340

  • Graduation: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on graduation)
  • Range: -200℃~1300℃ (varying depend on graduation)
  • Resolution: 0.1℃
  • Channels: RTD20 channels; thermocouple 40 channels; scan channel can off arbitrarily

Compare

AT4508

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4516

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Graduation: J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃(
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4724

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4724V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4732V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4740V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4748V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4756V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4764V

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4716

  • Graduation: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on graduation)
  • Resolution: 0.01℃
  • Channels: 16 channels;
Privacy | Term of Use | Help
©2005-2024 Changzhou Applent Instruments Ltd. 苏ICP备13026254号