AT9352 Battery Meter
ACTIVE
RS232RS485LANHANDLER
OVERVIEW
    FEATURES
    SPECIFICATIONS
    DOCUMENTATION
    NONE
    ACCESSORIES
    STANDARDS
    NONE
    OPTIONS
    NONE
    SOFTWARE
    NONE
    RELATED PRODUCTS

    Compare

    AT520L

    • Parameters: AC Resistance , DC voltage
    • Accuracy: R: 0.3%, V: 0.05%
    • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
    • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
    • Range: Automatic and manual with 6 ranges

    Compare

    AT525

    • Parameters: ACR DCV
    • Accuracy: R:0.5%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
    • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
    • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
    • Range: Automatic, Manual, Norminal, 4 ranges

    Compare

    AT526

    • Parameters: ACR, DCV
    • Accuracy: R:0.5% V:0.01%
    • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
    • Signal Source: AC 1kHz,Test current:<150mA
    • Range: Automatic & Manual, 7 ranges

    Compare

    AT526B

    • Parameters: ACR, DCV
    • Accuracy: R:0.5% V:0.01%
    • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
    • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
    • Range: Automatic & Manual , 5 ranges

    Compare

    AT526C

    • Parameters: AC Resistance, DC voltage
    • Accuracy: Resistance:0.5% ; Voltage:0.01%
    • Range: Resistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
    • Signal Source: AC 1kHz,Test current:<150mA
    • Range: 7 ranges, auto & manual

    Compare

    AT527

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

    Compare

    AT527A

    • Parameters: ACR, DCV
    • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
    • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
    • Signal Source: 1kHz, stable frequency: 20ppm
    • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

    Compare

    AT527B

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
    • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
    • Signal Source: 1kHz, Frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

    Compare

    AT527H

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
    • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

    Compare

    AT527L

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
    • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

    Compare

    AT528

    • Parameters: ACR, DCV
    • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
    • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
    • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
    • Range: 6 ranges, automatic, manual, nominal

    Compare

    AT528L

    • Parameters: ACR, DCV
    • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
    • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
    • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
    • Range: 4 ranges, automatic, manual, nominal

    Compare

    AT526G

    • Parameters: ACR, DCV
    • Accuracy: R:0.5% V:0.01%
    • Range: R:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
    • Signal Source: AC 1kHz,Test current:<150mA
    • Range: Automatic & Manual, 7 ranges

    Compare

    AT527F

    • Parameters: ACR, DCV
    • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
    • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
    • Signal Source: 1kHz, stable frequency: 20ppm
    • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

    Compare

    AT572B

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
    • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
    • Signal Source: 1kHz, Frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

    Compare

    AT527K

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
    • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1500.00V
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

    Compare

    AT529

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~400.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

    Compare

    AT529A

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~200.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

    Compare

    AT529B

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~800.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

    Compare

    AT529H

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~1000.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

    Compare

    AT527S

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
    • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~2000.00V
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

    Compare

    AT2527

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

    Compare

    AT2527L

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~60.0000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.
    Privacy | Term of Use | Help