AT2816A LCR Meter
ACTIVE
2021 Update Version
RS232RS485USB-232HANDLER
GPIBOPTIONS
SCPIMODBUS
DATA LOGGERUSB-DISK
OVERVIEW
    The AT2816A is the use of a high-performance processors and 3.5" TFT LCD screen smart LCR Meter. Since the SMD technology makes AT2816A portable.

    AT2816A offers wide frequency range (50Hz~200kHz 0.001Hz Step), programmable signal level (0.01V to 2.00V), auto range with 9 ranges, 30Ω/50Ω/100Ω constant output impedance and easy-to-use operation system.

    Built-in RS232C and handler interfaces help build an automatic component test system, communicate with the computer and analysis the test results.
FEATURES
  • True color LCD display.
  • Correction function: full range open circuit and short circuit
  • Multi-frequency sweep test: support 10 frequency sweep steps.
  • Multi-level test: support 10 level sweep steps.
  • File management: Built-in 10 files and External USB-Disk 10 files
  • Enhanced comparator (sorting) function: programmable P1~P9 9 Bins, main parameters HI, IN, LO display and output, NG, AUX, SREJ, IDX, EOM, etc.
  • Absolute deviation (ABS) comparison method, relative deviation (PER) and sequence (SEQ) comparison methods.
  • Switchable auxiliary gear (AUX) sorting.
  • Custom sorting result beep fetature.
  • Built-in RS232C interface and Handler interface.
  • Built-in RS485/USB interface. (For Rev.E Only)
  • Option: GPIB interface. (For Rev.E Only)
  • SCPI protocol and Modbus protocol.(For Rev.E Only)
SPECIFICATIONS
Test FunctionsCs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
Accuracy0.05%
Measurement Frequency50Hz~200kHz (Resolution 0.001Hz)
Measurement RangeAUTO/HOLD/NOMINAL 9 Ranges
Measurement Speed40 times/s, 10 times/s, 3 times/s
Display RangeL: 0.00001μH-9999.99H
C: 0.00001pF – 9999.99μF
R,X,Z: 0.00001Ω - 99.9999MΩ
D, 0.00001 – 9.99999
Q: 0.00001 – 99999.9
Δ%: -999999% - 999999%
θ(deg): -179.999° -179.999°
θ(rad):-3.14159 – 3.14159
DCR: 0.00001Ω ~ 99.9999MΩ
Source Resistance30Ω, 50Ω and 100Ω
Monitor ParameterZ, D, Q, θr, θd, R, X, G, B, Y, Vac, Iac, Δ, Δ%
Display Reader6 digits: 999999
Equivalent CircuitSerial and Parallel
Signal Level10.00mV~2.00V AC
100.0μA~20.00mA AC
Average1~256
Trigger ModeINT/HOLD/MAN/BUS
Trigger Delay0.01ms~60s
ComparatorOK: 10-BINS NG:1-BIN
AUX: 1-BIN
List Test10 Steps (Frequency/Voltage/Current)
Comparator ModeSEQ/ABS/PER
AdjustmentOPEN/SHORT Zeroing (ALL and 3-SPOT)
Filesbuilt-in 10 files and USB Disk 10 files
Data Logger9999 Log Files (.csv)
Beep FeatureOFF/PASS/FAIL
InterfaceRS232/RS485/USB/HANDLER/GPIB(OPTION)
(For Rev.E+ Only)
ProtocolSCPI/Modbus(RTU)
Other FunctionsAUTO LCZ
Power SupplyAC 85V-240V, 50Hz-60Hz
20W MAX
Dimension & Weight264(W)x107(H)x350(L)
3kg, net
APPLICATIONS
    Componets and materials measurement such as Inductor, Magnetic core, Ferrite core, Capacitor, Transformer and etc.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL108

ATL108

RS232通讯电缆

ATL501A

ATL501A

四端开尔文测试盒

ATL600

ATL600

ATL601

ATL601

OPTIONS

ATL508A

ATL508A

SOFTWARE
CH340 USB Driver
Rev.A1.0

Driver

SYSTEM

0.2MB

RAR

AT281X Data Acquisition Software
Rev.A1.0

CHINESE

Application

FREEWARE

5.4MB

RAR

AT281X Data Acquisition Software
Rev.A1.0

ENGLISH

Application

FREEWARE

4.9MB

RAR

Applent Communication Assist
Rev.4.23

CHINESE

Application

FREEWARE

2.4MB

RAR

RELATED PRODUCTS

Compare

AT2811

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.25%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: Auto/Hold, 6 ranges
  • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

Compare

AT2816B

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2817

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (16 Points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50/60/100/120/200/400/500/1k/2k/4k/5k/10k/20k/40k/100kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

Compare

AT3810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~200kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT610D

  • Test Functions: C,D
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: AUTO/HOLD 6 Ranges
  • Measurement Speed: 3times/s, 8 times/s, 20 times/s

Compare

AT810

  • Test Functions: L,C.R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD, 6 Ranges
  • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

Compare

AT810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

Compare

AT810D

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
  • Measurement Speed: 2 times/s, 5 times/s

Compare

AT817D

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
  • 20kHz,40kHz,50kHz, 100kHz
  • Measurement Range: AUTO/HOLD 6 Ranges

Compare

AT825

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT826

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT2617

  • Test Functions: Cs-Rs, Cs-D, Cp-Rp, Cp-D, Rs-Q,Rp-Q, Z-D, Z-Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100, 120, 1kHz, 10kHz, 100kHz 0.01%
  • Measurement Range: Auto, manual and standard , 9 range
  • Measurement Speed: 30t/s, 10t/s, 3t/s

Compare

AT827

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:

Compare

AT828

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:
Privacy | Term of Use | Help
©2005-2024 Changzhou Applent Instruments Ltd. 苏ICP备13026254号