AT610D Capacitance Meter
ACTIVE
Sorting machine Version
RS232
SCPI
OVERVIEW
    New 6th edition in 2021, AT610D redesigned with new technology, better stability, new key design, easier operation.

    AT610D adopts a high-energy processor and uses a smart capacitance tester with a bright color VFD screen.

    Built-in 100Hz, 120Hz, 1kHz and 10kHz test frequencies, and provide 0.1V, 0.3V and 1V test levels, so that it can fully meet the use of general production sites.

    Built-in RS232C interface, compatible with SCPI programming language, it is easy to communicate with computer and complete all instrument functions.

    Built-in Handler interface, cooperate with RS232C interface to complete complex automatic control system.
FEATURES
  • Display: 3-Lines VFD
  • Correction function: OPEN and SHORT
  • View: ΔABS, Δ% or Sorting Result on 3rd Line
  • Comparator Function: P1,P2,P3,NG,AUX; 9-Bins optional.
  • Interface: RS232C and Handler
  • 1000V DC Super-impact protection
SPECIFICATIONS
Test FunctionsC,D
Accuracy0.1%
Measurement Frequency100Hz,120Hz,1kHz,10kHz
Measurement RangeAUTO/HOLD 6 Ranges
Measurement Speed3times/s, 8 times/s, 20 times/s
Display RangeC: 0.01pF – 9999.9μF
D, 0.00001 – 9.99999
Source Resistance30Ω and 100Ω
Monitor ParameterΔ, Δ%
Display Reader5 digits: 99999
Equivalent CircuitSerial and Parallel
Signal Level10.00mV~2.00V AC
100.0μA~20.00mA AC
Trigger ModeINT/HOLD/MAN
Comparator5-BINS P1/P2/P3/AUX/NG
Comparator ModePER
AdjustmentOPEN/SHORT Zeroing
Beep FeatureOFF/PASS/FAIL
InterfaceRS232/HANDLER
ProtocolSCPI
Power SupplyAC 98V-240V, 50Hz-60Hz
15W MAX
Dimension & Weight264(W)x107(H)x350(L)
4kg, net
APPLICATIONS
    Componets and materials measurement such as Inductor, Magnetic core, Ferrite core, Capacitor, Transformer and etc.
    Capacitor Sorting machine
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATL600

ATL600

ATL601

ATL601

OPTIONS
NONE
SOFTWARE
Applent Communication Assist
Rev.4.23

CHINESE

Application

FREEWARE

2.4MB

RAR

RELATED PRODUCTS

Compare

AT2811

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.25%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: Auto/Hold, 6 ranges
  • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

Compare

AT2816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2816B

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2817

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (16 Points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50/60/100/120/200/400/500/1k/2k/4k/5k/10k/20k/40k/100kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

Compare

AT3810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~200kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT810

  • Test Functions: L,C.R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD, 6 Ranges
  • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

Compare

AT810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

Compare

AT810D

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
  • Measurement Speed: 2 times/s, 5 times/s

Compare

AT817D

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
  • 20kHz,40kHz,50kHz, 100kHz
  • Measurement Range: AUTO/HOLD 6 Ranges

Compare

AT825

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT826

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT2617

  • Test Functions: Cs-Rs, Cs-D, Cp-Rp, Cp-D, Rs-Q,Rp-Q, Z-D, Z-Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100, 120, 1kHz, 10kHz, 100kHz 0.01%
  • Measurement Range: Auto, manual and standard , 9 range
  • Measurement Speed: 30t/s, 10t/s, 3t/s

Compare

AT827

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:

Compare

AT828

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:
Privacy | Term of Use | Help