    The newly upgraded AT3810A adopt true color TFT-LCD display. Displayed in large fonts, readings are more intuitive.

    AT3810A with continuous frequency point of 10Hz~20kHz with a resolution of 0.001Hz. Test signal level 0.01Vrms ~ 2.00Vrms (10mV step), (add DCR measurement and internal DC bias (DC BIAS, ±2.5V)

    AT3810A can test the 4 parameters of the component at the same time. Each parameter can be arbitrarily configured. The newly improved instrument realizes full 6-bit display of the main and auxiliary four parameters.

    Can scan 10 kinds of frequencies or level lists, also be used for 3 groups users frequency be corrected to improve accuracy.

    Built-in comparator, through HANDLER interface combined with PLC to complete automatic sorting of components.

    Built-in RS232/RS485/USB interfaces and GPIB inteface optional, SCPI and Modbus support.
FEATURES
  • True color 16M color, TFT-LCD display.
  • Store 999 LCD screen files, trigger delay, automatic level control (ALC)
  • Correction function: full-scale open circuit and short-circuit sweep frequency clear, three groups of users point frequency calibration.
  • Multi-frequency test: support 10 frequency scan tests
  • Multi-level test: support 10 level scan tests
  • 10 sets of file management for full storage of instrument status, list scan settings and comparator settings.
  • Enhanced comparator (sorting) function: Programmable P1~P9 Nine-segment sorting, main parameters HI, IN, LO display and output, NG, AUX, SREJ, IDX, EOM, etc. Output.
  • Absolute deviation (ABS) comparison mode, relative deviation (PER) and order (SEQ) comparison.
  • Switchable accessory file (AUX) sorting.
  • Programmable from 1 to 200 times to provide stability.
  • Custom sorting results are heard.
  • Built-in RS232C interface and Handler interface.
  • 1000V super shock protection
SPECIFICATIONS
Test FunctionsCs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
AccuracySLOW/MED: 0.05%; FAST: 0.1%
Measurement Frequency10Hz~300kHz (Resolution 0.001Hz)
Measurement RangeAUTO/HOLD/NOMINAL 9 Ranges
Measurement Speed40 times/s, 10 times/s, 3 times/s
Display RangeL: 0.00001μH-9999.99H
C: 0.00001pF – 9999.99μF
R,X,Z: 0.00001Ω - 99.9999MΩ
D, 0.00001 – 9.99999
Q: 0.00001 – 99999.9
Δ%: -999999% - 999999%
θ(deg): -179.999° -179.999°
θ(rad):-3.14159 – 3.14159
DCR: 0.00001Ω ~ 99.9999MΩ
Source Resistance30Ω, 50Ω and 100Ω
Monitor ParameterZ, D, Q, θr, θd, R, X, G, B, Y, Vac, Iac, Δ, Δ%
Display Reader6 digits: 999999
Equivalent CircuitSerial and Parallel
Signal Level10.00mV~2.00V AC (ALC)
100.0μA~20.00mA AC (ALC)
DC BIAS-2.5V~+2.5V (0.5%+0.005V)
Average1~256
Trigger ModeINT/HOLD/MAN/BUS
Trigger Delay0.01ms~60s
ComparatorOK: 10-BINS NG:1-BIN
AUX: 1-BIN
List Test10 Steps (Frequency/Voltage/Current)
Comparator ModeSEQ/ABS/PER
AdjustmentOPEN/SHORT Zeroing (ALL,SPOT)
Filesbuilt-in 10 files and USB Disk 10 files
Data Logger9999 Log Files (.csv)
Beep FeatureOFF/PASS/FAIL
InterfaceRS232/RS485/USB/HANDLER/GPIB(OPTION)
ProtocolSCPI/Modbus
Other FunctionsAUTO LCZ
Power SupplyAC 100V-240V, 50Hz-60Hz
20W MAX
Dimension & Weight264(W)x107(H)x350(L)
3kg, net
APPLICATIONS
    Componets and materials measurement such as Inductor, Magnetic core, Ferrite core, Capacitor, Transformer and etc.
    Laboratory quality control
    Feed inspection
    Component sorting
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL108

ATL108

RS232通讯电缆

ATL501A

ATL501A

四端开尔文测试盒

ATL601

ATL601

OPTIONS

ATL508

ATL508

ATL608

ATL608

SOFTWARE
CH340 USB Driver
Rev.A1.0

Driver

SYSTEM

0.2MB

RAR

AT3818 Datalogger (External Trigger)
Rev.A1.0

CHINESE

Application

FREEWARE

3.2MB

RAR

Applent Communication Assist
Rev.4.23

CHINESE

Application

FREEWARE

2.4MB

RAR

RELATED PRODUCTS

Compare

AT2811

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.25%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: Auto/Hold, 6 ranges
  • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

Compare

AT2816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2816B

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2817

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (16 Points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50/60/100/120/200/400/500/1k/2k/4k/5k/10k/20k/40k/100kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

Compare

AT3816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~200kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT610D

  • Test Functions: C,D
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: AUTO/HOLD 6 Ranges
  • Measurement Speed: 3times/s, 8 times/s, 20 times/s

Compare

AT810

  • Test Functions: L,C.R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD, 6 Ranges
  • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

Compare

AT810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

Compare

AT810D

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
  • Measurement Speed: 2 times/s, 5 times/s

Compare

AT817D

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
  • 20kHz,40kHz,50kHz, 100kHz
  • Measurement Range: AUTO/HOLD 6 Ranges

Compare

AT825

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT826

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT2617

  • Test Functions: Cs-Rs, Cs-D, Cp-Rp, Cp-D, Rs-Q,Rp-Q, Z-D, Z-Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100, 120, 1kHz, 10kHz, 100kHz 0.01%
  • Measurement Range: Auto, manual and standard , 9 range
  • Measurement Speed: 30t/s, 10t/s, 3t/s

Compare

AT827

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:

Compare

AT828

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed: