AT817D LCR Meter
OBSOLETE
RECOMMENDED: AT3817A
RS232
SCPI
OVERVIEW
    AT817D with high preformance processor is a smart LCR test instrument with VFD screen. Some functions of AT817 have been streamlined, built-in 50Hz~100kHz 10 point test frequency, and provide 0.1V, 0.3V and 1V test levels. Compared with AT817, the price is more favorable, so that it can fully meet the use of most production sites.
FEATURES
  • High brightness, ultra-clear four-color VFD display.
  • Correction function: full range open circuit and short circuit sweep frequency clearing.
  • The third window can display Z, D, Q, ΔABS, Δ% or sorting results at the same time.
  • Comparator (sorting) function
SPECIFICATIONS
Test FunctionsL,C,R,Z,D,Q
Accuracy0.1%
Measurement Frequency50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
20kHz,40kHz,50kHz, 100kHz
Measurement RangeAUTO/HOLD 6 Ranges
Measurement Speed3times/s, 8 times/s, 20 times/s
Display RangeL: 0.001μH-9999.9H
C: 0.001pF – 9999.9μF
R,X,Z: 0.0001Ω - 99.999MΩ
D, 0.00001 – 9.99999
Q: 0.00001 – 99999.9
Source Resistance30Ω and 100Ω
Monitor ParameterZ, D, Q, Δ, Δ%
Display Reader5 digits: 99999
Equivalent CircuitSerial and Parallel
Signal Level10.00mV~2.00V AC
100.0μA~20.00mA AC
Trigger ModeINT/HOLD/MAN/BUS
Comparator5-BINS P1/P2/P3/AUX/NG
Comparator ModeSEQ/ABS/PER
AdjustmentOPEN/SHORT Zeroing-
Beep FeatureOFF/P1/P2/P3/AUX/NG
InterfaceRS232/HANDLER
ProtocolSCPI
Power SupplyAC 198V-240V, 50Hz-60Hz
15W MAX
Dimension & Weight264(W)x107(H)x350(L)
4kg, net
APPLICATIONS
    Componets and materials measurement such as Inductor, Magnetic core, Ferrite core, Capacitor, Transformer and etc.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL501

ATL501

Kevin clib

ATL600

ATL600

ATL601

ATL601

OPTIONS

ATL501A

ATL501A

四端开尔文测试盒

ATL508A

ATL508A

ATL608

ATL608

SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT2811

  • Test Functions: L,C,R,Z,D,Q
  • Accuracy: 0.25%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: Auto/Hold, 6 ranges
  • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

Compare

AT2816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2816B

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT2817

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50Hz~200kHz (16 Points)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 50/60/100/120/200/400/500/1k/2k/4k/5k/10k/20k/40k/100kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40/10/3 times/s

Compare

AT2818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

Compare

AT3810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3816A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~200kHz (Resolution 0.01Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3817A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT3818

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
  • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

Compare

AT610D

  • Test Functions: C,D
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
  • Measurement Range: AUTO/HOLD 6 Ranges
  • Measurement Speed: 3times/s, 8 times/s, 20 times/s

Compare

AT810

  • Test Functions: L,C.R,Z,D,Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD, 6 Ranges
  • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

Compare

AT810A

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
  • Accuracy: 0.05%
  • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
  • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
  • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

Compare

AT810D

  • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
  • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
  • Measurement Speed: 2 times/s, 5 times/s

Compare

AT825

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT826

  • Test Functions: L,C,R,Z
  • Accuracy: 0.2%
  • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
  • Measurement Range: -
  • Measurement Speed: 4 times/s, 1.5 times/s

Compare

AT2617

  • Test Functions: Cs-Rs, Cs-D, Cp-Rp, Cp-D, Rs-Q,Rp-Q, Z-D, Z-Q
  • Accuracy: 0.1%
  • Measurement Frequency: 100, 120, 1kHz, 10kHz, 100kHz 0.01%
  • Measurement Range: Auto, manual and standard , 9 range
  • Measurement Speed: 30t/s, 10t/s, 3t/s

Compare

AT827

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:

Compare

AT828

  • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
  • Accuracy: 0.2%
  • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
  • Measurement Range:
  • Measurement Speed:
Privacy | Term of Use | Help